Bridge Tronic Global
BTG Engineering ISO Class 6 cleanroom interior
ACS Certified · ISO 14644 · Valid Through May 2027

ISO 6 Cleanroom Facility

Purpose-built for optical, laser, and precision subassembly work — the controlled environment that legacy KLA semiconductor equipment demands.

ISO Class 6
Cleanroom Class
Class 1000 equivalent
ISO Class 8
Gown Room Class
Class 100,000 equivalent
20′ × 12′
Cleanroom Footprint
9 ft internal ceiling
12 Units
HEPA Fan Filter Units
2×4 ceiling-mounted FFUs
0.047″ WC
Positive Pressure
Maintained above ambient
ISO 14644
Certification Standard
At-rest particle compliance

Inside the Cleanroom

Modular acrylic wall system, epoxy floor, 12 ceiling-mounted HEPA fan filter units, and positive pressure maintained above ambient — the controlled environment where refurbishment and validation work is performed.

BTG Engineering ISO Class 6 cleanroom interior
BTG Engineering cleanroom entrance with safety interlocks

ACS Certificate of Compliance

The physical certificate is posted on the cleanroom door. The full test report — with particle counts across 10 measurement locations — is available to review or download below.

ACS Certificate of Compliance posted on the BTG Engineering cleanroom door

Certificate of Compliance posted on the cleanroom door — American Cleanroom Systems, NIST-Traceable instruments.

Certification Details
Certifying BodyAmerican Cleanroom Systems (ACS)
ClassificationISO Class 6 / Class 1000
StandardISO 14644 — At-Rest Compliance
Date TestedMay 4, 2026
Valid ThroughMay 4, 2027
Testing MethodClimet CI-150t, NIST-Traceable
Test Locations10 measurement points (cleanroom + gown room)
ClientBridge Tronic · 1360 Reynolds Ave, Irvine CA

What ISO Class 6 means in practice

ISO Class 6 permits a maximum of 35,200 particles (≥0.5 µm) per cubic meter at rest. This controlled environment supports contamination-sensitive work involving legacy KLA optical subassemblies, laser paths, detectors, and precision components where particle control is important to handling, service, and validation.

What the Cleanroom Enables

The cleanroom isn't a credential — it's a prerequisite for the work. Legacy KLA systems fail when environmental contamination enters subassemblies that were designed for fab-floor cleanliness standards.

Optical Component Handling

Laser optics, beam splitters, and sensitive detector assemblies serviced in a particle-controlled environment to prevent contamination-induced measurement drift.

Laser Subassembly Work

Class 3B laser systems serviced under controlled conditions with dedicated safety interlocks — the same hazard class as the KLA systems we support.

Refurbishment & Rebuild

Full system refurbishment requiring clean conditions — optics replacement, sensor calibration, and final performance validation — all performed in-spec.

Pre-Ship Validation

Refurbished and repaired systems validated in the cleanroom prior to shipment, matching the environmental conditions of your fab floor.

Irvine, California

1360 Reynolds Ave, Suite 102
Irvine, CA 92614

Equipment accepted for refurbishment, evaluation, and component-level repair. Contact engineering to discuss logistics, scope, and timeline before shipping.

Ready to start a refurbishment project?